Re: [Amps] load capacitor ratings?

To: "amps@contesting.com" <amps@contesting.com>
Subject: Re: [Amps] load capacitor ratings?
From: Will Matney <craxd1@ezwv.com>
Date: Mon, 30 Aug 2004 21:20:54 -0400
List-post: <mailto:amps@contesting.com>
I failed to mention that the values I were mentioning earlier, in the designs I was using, were for a Pi tank circuit and not a Pi-L. Thus the load C would have seen a different load resistance of about 300 ohms or so. For 1500 watts PEP on a 300 ohm load, a voltage of 671 volts would be incurred. At the 50 ohm load for a Pi tank, load C would see about 274 volts. So a capacitor with a rating of at least 2.5 : 1 difference would be needed. Where V = sqrt of W x R.