To: | amps@contesting.com |
---|---|
Subject: | [Amps] Centurion cooling ideas for AM service |
From: | "Rob Atkinson, K5UJ" <k5uj@hotmail.com> |
Date: | Thu, 26 Aug 2004 15:37:59 +0000 |
List-post: | <mailto:amps@contesting.com> |
Thanks Rich for this information; it makes the fan on top blowing down on
the Centurion anode heat sinks more important since they are the flat type
spreading out horizontally. I guess these are supposed to be used for air
blowing up from the bottom but Ten Tec used them because they fit inside the
cabinet. The types used by QRO would stick too high up. Also, the stock
fan is, according to your measurement, too small at 119 mm on a side. The
cabinet is too low height to fit a 150 mm fan so the additional fans I have
planned seem to be important. Can anyone suggest a vendor for Comair-Rotron fans? re Transformer ratings, the Dahl h.v. unit in mine is speced by Dahl at 2225 v. 500 ma CCS (AC I imagine). tnx 73, Rob/K5UJ
_________________________________________________________________ Don?t just search. Find. Check out the new MSN Search! http://search.msn.click-url.com/go/onm00200636ave/direct/01/ _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |