Amps
[Top] [All Lists]

Re: [Amps] 4-1000A in Passive grid-driven use?

To: n7ioh <n7ioh@cybertrails.com>
Subject: Re: [Amps] 4-1000A in Passive grid-driven use?
From: R.Measures <r@somis.org>
Date: Wed, 28 Apr 2004 20:39:43 -0700
List-post: <mailto:amps@contesting.com>

On Apr 28, 2004, at 12:38 PM, n7ioh wrote:


Are there any problems in using the 4-1000A in a passive grid-driven mode on 160 - 10 meter or on 6 meters?

 Above 30m, it's a good idea to tune out the grid's XC. See:
http://www.somis.org/D_a_05.GIF
The XL of L1 tunes out the grid's XC for whatever frequency you choose. note -- this is the first step in tuning up such a machine. .


If not, what kind of output can I expect to get?

 Depends on anode V and screen V. With 7kV and 1kV, you should be able to get 2.6 out.


Second, I have seen amps that use a roller inductor and not a band switch, any thoughts?

 They provide the best match over a wide frequency range.


Richard L. Measures, AG6K, 805.386.3734. www.somis.org