That will provide plenty of pressure at 1700-rpm, even for the
8171's big brother.
cheers
On Apr 11, 2004, at 10:31 AM, kenw2dtc wrote:
The pressure drop as well as the noise drop will be exponential.
However, if a tube with a large anode cooler is used - such as an 8171
- a 1700-rpm blower will usually do the job, especially for SSB and
telegraphy. What is the diameter of the squirrel cage, Ken?
*******Rich, The diameter of the blade is 9.5 inches.
*******Thanks,
*******Ken W2DTC
On Apr 10, 2004, at 9:13 PM, kenw2dtc wrote:
Hi,
I have a Dayton pressure blower that puts out 820 CFM with a 3450 RPM
1/3 HP motor. If I substitute a 1725 RPM 1/4 HP motor will the CFM
drop
in
half? Will the roaring sound drop accordingly also? I hope there is
a
straight formula rather than working with fan diameter and number of
blades
etc?
73,
Ken W2DTC
Rich Measures, AG6K, 805.386.3734. www.somis.org/