At 04:56 PM 1/31/2004, K3vw@aol.com wrote:
You can use a 3-500Z chimney with the 3CX1200A7, Ameritron does !
Willy K3VW
So, if the Coleman lantern double mantle chimney works with a 4-400A
and that is the same size as a 3-500Z and if the 3-500Z chimney
works on the 3CX1200A7 then it sounds like the Coleman
lantern double mantle chimney should work with a 3CX1200A7.
Can anyone confirm that this is the case? Don't know the price of
the Coleman lantern chimney these days but it used to be a
relatively inexpensive way to get Pyrex glass for your 4-400As.
Since I have a couple of 3CX1200xx tubes (A7 and Z7) but no
chimneys this would be a good thing to know. Except for the
fact that a clear chimney is a real waste with an external anode
tube.
--John W0UN
------------------------------------------------------------------------
---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.564 / Virus Database: 356 - Release Date: 1/19/2004
------------------------------------------------------------------------
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps