My experience with Eimac 4CX250B tells me that it needs at least 30 seconds
warm-up, preferably 2-3 minutes.
I doubt that the RCA version is different. The 250 is a indirectly heated
oxide cathode tube.
Helge
LA6MV
-----Original Message-----
From: GGLL [mailto:nagato@arnet.com.ar]
Sent: 18. juni 2003 14:27
To: Amplificadores Lineales
Subject: [Amps] 4CX250B/F
Reading RCA manual I've seen that 4CX250B (6V heater) tube requires
no warm-up period, but 4CX250F (26 V heater) a 30 seconds period, why
the difference?
Best regards and TIA
Guillermo - LU8EYW.
_______________________________________________
Amps mailing list
Amps@contesting.com