Thanks for the e-mail Sam - never thought of that but this time it seems to be
something else also, the 50 ma Ip ''in stand by'' - as soon as I switch the
amp on the meter reads 50 mA - never happened before, this indication on
the meter also when everything is disconnected except the 220V AC cord!
All the best to you and yours and 73/DX de Osten SM5DQC
----- Ursprungligt meddelande -----
Fr?n: "S. J. Blackwell" <w5lu@hotmail.com>
Till: <sm5dqc@algonet.se>; <oz1pif@get2net.dk>; <amps@contesting.com>
Skickat: den 8 april 2003 16:35
?mne: Re: [Amps] Need help Yaesu FL2100Z
> I once bought a 4x811A amp that was described as having something wrong with
> the circuit because one tube would consistantly glow red and eventually burn
> a hole in the plate. This occured even though this tube had been replaced on
> two occasions. The problem was the other three tubes were way down on
> emission and the sinlge tube was getting a great deal of abuse. I am not
> suggesting this is your problem as I understand that you have already
> swapped the tubes to another amp, but I found it interesting.
> Gud luck,
> Sam, W5LU.
>
>
>
>
>
>
> >