>Dear Sam, et. al.,
>    The high voltage is read from a voltage divider R3 and R4 which go from
>the high voltage wiring to ground.  The connection between R3 and R4 is
>wired to terminal 11 on the meter switch.
>    My first guess is one of the three resistors making up R3 has opened up.
>R3 is made up of Three 4.7 MegaOhm resistors in series.  It may just be time
>to replace those three resistors.  The other possibility is that R4 has
>shorted to ground so both sides of the meter switch are to ground in the HV
>position.  R4 is supposed to be 15KiloOhms.  Since there is over 2000 volts
>HV, I would use three 2-watt resistors to replace the existing R3.


Good advice, George.  However, 2w film-type resistors should be used.  I 
would also add 3A glitch protection diodes across the 200uA meter 
movement.
>
>
>----- Original Message -----
>From: "Samuel Ramac" <samuel_ramac@hotmail.com>
>To: <amps@contesting.com>
>Sent: Saturday, April 05, 2003 7:05 AM
>Subject: [Amps] SB-200 HV meter problem
>
>
>> I have another SB-200 question.. (Sorry for all the questions, just got
>this
>> amp and is my 1st.)
>>
>> When I measure HV my meter does not do anything.  Except for this
>problem,
>> the amp seems to work well (600W on most bands).  The meter seems to work
>> well indicating the plate current, SWR, grid current, and relative power.
>>
>> Any ideas?  Thanks
>>
>> Sam N2MXY
>>
>>
>>
>> - - - - - - - - - - - - - - - - - - - - - - - -
>> Samuel C. Ramac
>> samuel_ramac@hotmail.com
>>
>>
>>
>>
>>
>>
>> _________________________________________________________________
>> MSN 8 helps eliminate e-mail viruses. Get 2 months FREE*.
>> http://join.msn.com/?page=features/virus
>>
>> _______________________________________________
>> Amps mailing list
>> Amps@contesting.com
>> http://lists.contesting.com/mailman/listinfo/amps
>>
>>
>
>
>_______________________________________________
>Amps mailing list
>Amps@contesting.com
>http://lists.contesting.com/mailman/listinfo/amps
>


-  R. L. Measures, a.k.a. Rich..., 805.386.3734, AG6K, 