Friends, What is the recommended method to pre-condition a "USED" pair of 3CX800A7's. These tubes have been out of service for a couple of years and I need to replace a pair of flat 3CX800A7's in my Lunar-Link, 2 mater, PA. Is is recommended to leave filament voltage on for several hours before applying HV? Is it recommended to leave HV turned on before applying drive power? I've looked through EIMAC's "Care and Feeding of Power Grid Tubes" but can not find any reference to pre-conditioning tubes for use. Thanks for your input. Dave / W6TE |