>> I'm wondering if someone can explain why AB2 GG 
>>service is more linear than AB2 grid-driven service?
-
One contribution is the swamping effect for the "feed 
through" or "feed forward" power from the driving source. 
-
The terms can be misleading, as that portion of the drive 
power does not appear in the plate load circuit of the 
GG stage until after it is converted to a varying dc plate 
potential effectively in series with the main amplifier 
power supply. 
-
The "converted drive power" serves a useful function in 
linear amplifier service because it swamps out the 
undesirable effects of nonlinear grid loading and presents 
a reasonably constant load to the exciter. 
-
cheers.
skipp