I saw an article one time where a guy moved a RFC resonance in a pre
warc Alpha by making a single shorted turn of insulated wire on the coil
form.It was slid along the form until the resonance was in the desired
spot. You could use teflon spagetti  on a piece of buss wire. 73, Dan,
N5AR

carl seyersdahl wrote:
> 
> How far away from a given band should a plate choke resonance be to not
> cause a problem?? I have a resonance right on 18 mhz. in an amp, and am
> concerned that someone might want to use it on 18 mhz. and so I want to move
> it, but should I move it up or down , and if so how much??? Any thoughts on
> this will be appreciated!!
>  carl / kz5ca
> 