rich Wrote:
>>>URLs? Bibliographies?
>>
>>For my point of view, please see:
>> http://www.ifwtech.com/g3sek/boards/tetrode/tetrode-3.htm
>>
>Voltage regulation measurements would be nice.
I don't quote the figures because they're almost embarrassingly good.
The output regulation, hum and noise are all typically below 100mV - a
4-1/2 digit DVM doesn't flicker between no load and full load. That's
certainly better than any power tetrode actually needs, but it's what
the active regulator happens to deliver.
>Were the IMD measurement relative to PEP or to the two tones?
Relative to either of two equal tones, so they all look 6dB higher than
the ARRL-style presentation (which is below PEP). More important are the
differences between them.
--
73 from Ian G3SEK Editor, 'The VHF/UHF DX Book'
'In Practice' columnist for RadCom (RSGB)
http://www.ifwtech.com/g3sek
--
FAQ on WWW: http://www.contesting.com/FAQ/amps
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
|