To fully understand the function of this cap, one must make a Scattering
Parameter Analysis of the stages, the generator and it's load. A simple
Smith Chart is just a beginning, a tool that can induce substantial
errors
if the assumptions made about inputs and outputs are wrong. I will
suggest
you to use MWOffice for a comprehensive analysis of the amp. You might
have
to make the S parameter list for the tube or perhaps the manufacturer had
done so already.
Good luck
Alex
http://www.sandlabs.com
----__JNP_000_034e.2f9f.0bde
Content-Type: text/html; charset=us-ascii
Content-Transfer-Encoding: quoted-printable
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META content=3D"text/html; charset=3Diso-8859-1" http-equiv=3DContent-Type>
<META content=3D"MSHTML 5.00.2614.3500" name=3DGENERATOR>
<STYLE></STYLE>
</HEAD>
<BODY bgColor=3D#ffffff bottomMargin=3D0 leftMargin=3D3 rightMargin=3D3 =
topMargin=3D0>
<DIV>Hi Alex,</DIV>
<DIV> Not my job! :-)</DIV>
<DIV> </DIV>
<DIV> I'm already over the limit of my curiosity on this=
=20
one.</DIV>
<DIV> </DIV>
<DIV>73 & Good morning,</DIV>
<DIV> Marv WC6W</DIV>
<DIV> </DIV>
<DIV> </DIV>
<DIV>On Sun, 2 Dec 2001 03:19:28 -0500 "alex" <<A=20
href=3D"mailto:alex@sandlabs.com">alex@sandlabs.com</A>> writes:</DIV>
<BLOCKQUOTE=20
style=3D"BORDER-LEFT: #000000 2px solid; MARGIN-LEFT: 10px; PADDING-LEFT: =
10px">
<DIV>To fully understand the function of this cap, one must make a=20
Scattering<BR>Parameter Analysis of the stages, the generator and it's =
load. A=20
simple<BR>Smith Chart is just a beginning, a tool that can induce =
substantial=20
errors<BR>if the assumptions made about inputs and outputs are wrong. I =
will=20
suggest<BR>you to use MWOffice for a comprehensive analysis of the amp. =
You=20
might have<BR>to make the S parameter list for the tube or perhaps the=20
manufacturer had<BR>done so already.<BR><BR>Good luck<BR>Alex<BR><A=20
href=3D"http://www.sandlabs.com">http://www.sandlabs.com</A></DIV></=
BLOCKQUOTE></BODY></HTML>
----__JNP_000_034e.2f9f.0bde--
________________________________________________________________
GET INTERNET ACCESS FROM JUNO!
Juno offers FREE or PREMIUM Internet access for less!
Join Juno today! For your FREE software, visit:
http://dl.www.juno.com/get/web/.
--
FAQ on WWW: http://www.contesting.com/FAQ/amps
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
|