| 
>
>The only way to properly set the transformer taps is to
>measure the filament voltage at the tube pins at each
>setting.
//  Amen, Phil
> I would start with the 220 volt tap first. If the voltage
>is within specs, you are there!
//  However, operating a 5v +/- 5% filament at 5.25v instead of 4.75v 
will reduce emissive life to [4.75v/5.25v] ^23.4 =  c. 1/10 of normal 
life.  
>
>...
-  R. L. Measures, 805.386.3734, AG6K, www.vcnet.com/measures.  
end
--
FAQ on WWW:               http://www.contesting.com/FAQ/amps
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
 |