> For a schematic, see page 9 of:
> http://www.ameritron.com/ameritron/manuals/pdf/al811h.pdf
> In contrast, the FL-2100Z "neutralization" is very hit-and-miss,
> because the amplitude and phase of feedback depends on all three
> pi-tank settings.
>
> 73 from Ian G3SEK Editor, 'The VHF/UHF DX Book'
> 'In Practice' columnist for RadCom (RSGB)
> http://www.ifwtech.com/g3sek
You sure are right there Ian! There is no WAY that is a good idea!!!!
The phase and level of the feedback would be all over the place
with tank settings and load impedance, and would likely never be
correct. It could make thinks worse rather than better.
That's a very poor system, and it may actually make things worse.
73, Tom W8JI