>On Wed, 6 Dec 2000 09:48:45 -0600 , Brakob, Hans wrote:
>
>>Just installed a new AL-1200 yesterday.
>>The blower is kinda loud, like sitting in the back row of a DC-9 with full 
>reverse thrusters.
>>I notice the blower has wiring options for 4 speeds (it comes wired for 3rd 
>gear).
>>Has anyone rewired for lower speeds and used the amp for contesting?  
>_____________________________________________________________________
>
>I can only offer some advice if you're planning on using the AL-1200
>for RTTY.  I had one several years ago and smoked the 80/160 tank coil
>twice while RTTY contesting.  IOW, the AL-1200 cooling is marginal for
>full-power, full-carrier operation.  I'd be careful about reducing the
>fan speed.  After replacing the tank coil, I held it to less than 1 kW
>out and had no problems.  
>
>The problem is that the exhaust air from the tube is dumped into the
>cabinet rather than being vented outside. .....