>2. As alternative use a number of paralell cheap russian TV sweep tubes
>with filaments in series to get rid of the filament transformer weight.
Use
>voltage qudrupling straight from 230 VAC mains with a well isolated
chassie
>to avoid electrical chocks. At the expected 500 W level use an outdoor
500W
>SMART TUNER and a long wire.
HyGain did this a number of years ago with a CB / 10 meter amplifier called
the "afterburner".
It wasn't very popular, since you had to run an "unearthed" station,
however, it did work respectably.
If memory serves me well (I didn't like the amp very much, so I rarely
worked on them / owned one) it had a single 6JT6 tube driving a pair of
6LQ6s or something of that nature. Maybe a flat 4 6JT6s. Been awhile.
Anywho, the point was that a commercial venture did the voltage multiplier
off the mains trick. Just be careful.