>Subject: Re: [AMPS] Emtron DX1
>
>
>> >
>> >My suggestion is this; for a permanent totally silent fix for your DX-1.
>> >There is a large company here in the USA called W.W. Grainger.
>> >They have all of the parts I am about to suggest.
>> >
>> >Since the fan is bolted to the rear of the cabinet outboard of the chassis,
>> >it can easily be removed, and a suitable plenum fabricated to cover
>> >the hole and adapt a 3 inch common clothes drier hose in its place.
>> >On the other end of the hose, a suitable adapter is made to adapt the
>> >hose to the centrifugal blower that you select for the job. The longer the
>> >hose,
>> >the bigger the blower you will need. Here at 600 feet above sea level, I
>> >have a 1/12 HP blower feeding 25 feet of 2 1/2 inch hose, and it delivers
>> >over 250 cfm of air to a pair of 4CX1500B's.
>>
>> What is the water-column pressure measured at the tube socket?
>> thanks
>
>Quite a bit more than the stock internal blower. Exaust air flow nearly
>doubled in pressure due to the size of the remote blower.
>
''Quite a bit'' is not much help. I need a measurement. // I am going
after the statement of ''over 250 cfm...''. Just because the blower
manufacturer says congratulations, you have purchased a 250cfm blower
does not mean that it will actually do 250. . Eimac says that at sea
level, it takes 0.6" of pressure to flow 34cfm in a 4CX1500B. My guess
is that to put 250cfm through a pair of 1500B coolers, it would take a
Force-4 hurricane.
- cheers, Phil.
- Rich..., 805.386.3734, www.vcnet.com/measures.
end
--