Hi all,
> >> Two tubes requires that L be cut in half and C-tune be doubled to
> >> maintain the same Q. Guessing at tank values is not good engineering
> >> practice.
Right. And reducing the number of turns from 3 to 1.5 doesn't
reduce the L by 50%. In general, halving the number of turns in a
coil reduces the inductance by a factor of four. L is proportional to
N-squared.
73,
George T. Daughters, K6GT
--