Well...........Looks like the amp is fixed....When I first started, the 2.5
Mh choke that is across the output of the tank (prevents high voltage from
appearing on antenna if the DC blocking caps shorts), was burned open. I
replaced it with a 220K 2 watt resistor. (A trick I had learned from Rich
Measures). I installed a 2.4 Mh choke and the arcing stopped completely.
Even removed all of the nicrome wire suppressers.
What would cause the choke to open. ?
Thanks and Happy Thanksgiving to all!!!
Jim W7RY
-----Original Message-----
From: Jim <jdc@ieway.com>
To: amps@contesting.com <amps@contesting.com>
To: <amps@contesting.com>
Date: Wednesday, November 24, 1999 6:04 AM
Subject: [AMPS] Band Switch arcing SB-1000/AL-80
>
>I know there was a thread about this a bit ago........But.......
>
>
>The arcing that I am having is in the front wafer of the switch. This
wafer
>just switches the tuning cap padder for 160 meters. The
>cap is 170 Pf. The open contacts arc when in the 80 meter position. I am
>not sure if it is a parasitic or not. I would say not.
>
>Riches special plate suppresser is installed in the plate lead. The gap
>that arcs is almost 3/4 inches wide! Why does the tune cap itself arc ?
>
>Did Ameritron re-design this portion of the switch ?
>
>I really do not want to replace an $ 80.00 switch. Let alone the fuss of
>replacing it.
>
>73 to all and happy Thanksgiving....
>
>Jim W7RY
>
>
>
>
>--
>FAQ on WWW: http://www.contesting.com/ampsfaq.html
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>Search: http://www.contesting.com/km9p/search.htm
>
>
--
FAQ on WWW: http://www.contesting.com/ampsfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
Search: http://www.contesting.com/km9p/search.htm
|