For your info, that switch is effectively mall but not so much as it might
be thought.
Since 1988, what it was my SB220 has a 3CX1200 replacing the paired 3-500, a
forced cooling system with chimney (in other words no air to the switch), an
external PS with a full wave rectifier and the transformer has a
secondary of 3300V AC 1.2A.
Even like that, there's no bandswitch failure to report in spite that the
operator is a contester.

73,
Mauri I4JMY

PS In a standard SB 220 the RF current is no more than 5-6 A.



-----Messaggio Originale-----
Da: sm5ki <sm5ki@algonet.se>
A: measures <measures@vcnet.com>; AMPS <amps@contesting.com>
Data invio: mercoledì 10 novembre 1999 21.31
Oggetto: SV: SV: [AMPS] Re: SB220 problem


>
> Thanks Rich but you must agree two paralellt tiny receiving type switch
> contacts is not what you want to have when things go rough after your
tenth
> beer in the night or in a contest. Hej daa de Hans.



--