Hi Carsten
No special relay needed here. I use SPST 30 amp relays here that I
found at an electronic surplus store. They are about 1 X 2 X 2 inches
in size and come in 12 or 24 volt dc coils. The contacts on these are
comparable to the solenoids on the Henry 8K-Ultra, so I knew they
would take the suds OK.
(((73)))
Phil, K5PC
>Hi,
>
>I'am looking for a couple of relays for switching
>in extra capacitance at the Load capacitor in my
>YC156 Amplifier. The Vaccum cap is a 10..1000 pF
>15KV/80Amp Jennings, and I need around 3000 pF on
>160M and around 1500 pF on 80M. So I need to
>switch in 1000 pF on 80M and in additioan to that,
>an extra 1500 pF on 160M.
>
>How do I do that ? What type of relay to use ? Maybe its
>way out, but I can get some Contactors with 4 sets of
>contacts, each rated at 25Amp, ofcourse at 50 Hz. I thought
>of paralleling the four contact sets on each relay. Isolation
>between contact sets/coil is > 4KV. Is it impossible to
>use two relays like this, or do I have to get something else ???
>
>Thanks,
> Carsten OZ9AAR
> http://www.magicio.com/cgroen
>
>--
>FAQ on WWW: http://www.contesting.com/ampsfaq.html
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>Search: http://www.contesting.com/km9p/search.htm
>
--
FAQ on WWW: http://www.contesting.com/ampsfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com