In case anyone cares, the bug is in the brain. The inductance is not directly
proportional to the number of turns, it's proportional to the square root of the
number of turns. 21 turns is exactly 2.2 uh. Duh.
73,
Vic, K2VCO
Fresno CA
Vic Rosenthal wrote:
> Naturally, they don't give the
> inductance, but according to the Amidon data sheet, 21 turns on a T50-2 is
> about
> 10 uh.
>
> When I run the calculation (Q = 2.5, input impedance 57 ohms) I get cin =
> 1006,
> cout = 984, and l = 2.2 uh. I think my inductance value is closer to being
> right.
>
> Is this just another bug in the handbook? Or is the bug in my personal
> brainware?
--
FAQ on WWW: http://www.contesting.com/ampsfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
Search: http://www.contesting.com/km9p/search.htm
|