Ian said :
> The real problem is that there are so many meters out there with poor
peak-reading circuits.....
Amen
What is needed is a careful design of the filters associated with the meter
output.
Suppose one stacked two time-constants with one having a 0.1 second tau and
another with say a 3 second tau? The fast one would ollow enough of the
envelope to get through so that one could see what is going on. It would more
or less follow the syllabic peaks. The second tau would be holding the
average value, more or less. Some experimenting would be required to
ascertain the most practical values.
Regards,
Bill W KB7YUM
--