Amps
[Top] [All Lists]

[AMPS] Blower Noise Problem

To: <amps@contesting.com>
Subject: [AMPS] Blower Noise Problem
From: measures@vc.net (Rich Measures)
Date: Sat, 24 Jul 1999 18:49:39 -0700


>
>I have a McClean Engineering 115vac capacitor-start
>blower that puts out white noise on 160 meters.
>
Capacitor-start motors are typically used in compressors where the motor 
must start against a heavy load.  Blower service is quite the opposite.  
If you measure c. 130 -160 vac across the capacitor when the motor is 
running, you have a capacitor-run motor.  

>Anyone have a proven circuit for cleaning up my act?
>
Something may be in the process of breaking down, Phil.  I would 
sustitute a similar capacitor to find out whether the RFI is coming from 
the capacitor or from the motor.  

-  good luck



Rich...