>I have a McClean Engineering 115vac capacitor-start
>blower that puts out white noise on 160 meters.
>
Capacitor-start motors are typically used in compressors where the motor
must start against a heavy load. Blower service is quite the opposite.
If you measure c. 130 -160 vac across the capacitor when the motor is
running, you have a capacitor-run motor.
>Anyone have a proven circuit for cleaning up my act?
>
Something may be in the process of breaking down, Phil. I would
sustitute a similar capacitor to find out whether the RFI is coming from
the capacitor or from the motor.
- good luck
Rich...
R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures
--