>I am beginning the process of winding some toroid coils that are going to be
>used in a 1500 watt hf amp. The cores are T-225 and are supposedly good for
>1500 watts but I figure to be safe I will use two sandwiched together.
>Questions:
>
>1. Do the two toroid cores need to be insulated from each other 

?  no

> or can I
>just place them tightly next to each other and then wrap them as a package?
>
?  yes.  A suitable wrap is self-sticking tape.     It has no adhesive.  
.It has good RF properties and it conforms like it was paint.   Plymouth 
Rubber Co. makes the stuff.  .  
http://www.plymouthrubber.com/products/special-products.htm
..........
>3. I am using teflon insulated wire. Do I need to insulate the cores before
>applying the wire?
>
?   Teflon is easy to  cut.    self-sticking tape makes a good cushion 
for it.  

-  later, Lane


Rich...

R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures  


--