Amps
[Top] [All Lists]

[AMPS] measuring meter shunt resistance

To: <amps@contesting.com>
Subject: [AMPS] measuring meter shunt resistance
From: measures@vc.net (Rich Measures)
Date: Thu, 17 Jun 1999 23:37:07 -0700


>
>Gents,
>Is there a simple way to accurately measure the low resistance of a current
>meter shunt? I am trying to get my plate current and grid current meters
>calibrated and I need to verify the values of the shunt R but the Ip shunt
>is less than .3 ohms and the Ig shunt is less than 1.6 ohms. My Fluke 77BN
>is of no real help at these low values.
>
?  One way to measure low resistance values is to put 1.000 ampere 
through the unknown resistance.  Measure the potential across the unknown 
resistance with your Fluke.  1mV=1milli-ohm.  

-  later, Lane
>--
>FAQ on WWW:               http://www.contesting.com/ampfaq.html
>Submissions:              amps@contesting.com
>Administrative requests:  amps-REQUEST@contesting.com
>Problems:                 owner-amps@contesting.com
>Search:                   http://www.contesting.com/km9p/search.htm
>



Rich...

R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures  


--
FAQ on WWW:               http://www.contesting.com/ampfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm