>Gents,
>Is there a simple way to accurately measure the low resistance of a current
>meter shunt? I am trying to get my plate current and grid current meters
>calibrated and I need to verify the values of the shunt R but the Ip shunt
>is less than .3 ohms and the Ig shunt is less than 1.6 ohms. My Fluke 77BN
>is of no real help at these low values.
>
? One way to measure low resistance values is to put 1.000 ampere
through the unknown resistance. Measure the potential across the unknown
resistance with your Fluke. 1mV=1milli-ohm.
- later, Lane
>--
>FAQ on WWW: http://www.contesting.com/ampfaq.html
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>Search: http://www.contesting.com/km9p/search.htm
>
Rich...
R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures
--