NS1Z says;
>The tube anode was supplied by 28 modules @ 1 kV each. Solid state
>control switched in the number of modules required via fiber optic control
>lines.
A bit bigger than I was thinking of! I've heard of the California
kilowatt but....
An interesting technique. Tnx, John.
How did they handle tank circuit dissipation? I did some sums, and if you
have an unloaded coil Q of 100 and a working Q of 10, approximately 13% of
output power is dissipated in the tank. From experience, I don't believe
that unloaded tank coil Q's of much above 100 - 200 are practicable.
73
Peter G3RZP
--
FAQ on WWW: http://www.contesting.com/ampfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com