To: | <amps@contesting.com> |
---|---|
Subject: | [AMPS] Bias for SB-220 |
From: | Peter_Chadwick@mitel.com (Peter Chadwick) |
Date: | Wed, 2 Jun 1999 14:25:23 +0100 |
>The real problem is wasted power and heat. Letting the bias run in > full-tilt on condition is like putting a 600-1000 watt space heater > the room. So how much dissipation do you save? Assuming that you bias the PA off totally during receive, how much does the dissipation go down by reducing dissipation at the syllabic rate? Especially as the bias switching isn't affected by the peak to average ratio? 73 Peter G3RZP -- FAQ on WWW: http://www.contesting.com/ampfaq.html Submissions: amps@contesting.com Administrative requests: amps-REQUEST@contesting.com Problems: owner-amps@contesting.com Search: http://www.contesting.com/km9p/search.htm |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [AMPS] Bias for SB-220, Tom Rauch |
---|---|
Next by Date: | [AMPS] Re: Ferrite Rod for 6M Amp, Jon Ogden |
Previous by Thread: | [AMPS] Bias for SB-220, Peter Chadwick |
Next by Thread: | [AMPS] Bias for SB-220, Tom Rauch |
Indexes: | [Date] [Thread] [Top] [All Lists] |