In the July 1985 issue of 73, WB2WIK, had a detailed writeup of a 4-1000A amp
for 6 meters.
He used a 5-55 pf vacuum variable cap (ITT/Jennings GCS-55), 3 turns of 1/4
inch copper tubing on a 1 and 3/4 inch form which when the form was removed, it
was stretched out to 3 1/4 inches long, and 20-200 pf loading cap (E. F.
Johnson 167-12).
It ran on 4KV on the plate. Claimed 80 watts in gave 1.8 KW out. Did not state
the efficiency.
I can send a copy of the article if you would like.
Sorry, no cap.
73, Harry, W3IIT
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
At 03:52 PM 5/20/99 -0400, Dick McDuffie wrote:
>
>I'm looking for a 25 or 30 PF vacuum variable at least 10KV, I got my
>4-1000A amp running on 6M with a 500 PF cap using the "tap the tuning cap
>off the coil" trick, but I can't get any efficiancy out of it, good output
>peak at about 78PF but only 26% eff! I'm going to build a separate 6M deck,
>have abt everything but the small cap. If you have one please reply with
>price shipped to Maine.
> Thanks, Dick NY1E
>
>
>--
>FAQ on WWW: http://www.contesting.com/ampfaq.html
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>Search: http://www.contesting.com/km9p/search.htm
>
>
>
<center>Visit the Mt. Airy VHF Radio Club at:
<underline><color><param>0000,0000,fefe</param>http://www.ij.net/packrats/
</color></underline>Info on VHF/Microwave Nets, Beacons & Subscription to
Cheesebits
Currently running a series on 24 GHz Transverters
Beacons at 50.080, 144.284, 222.065, 432.295, 903.071, 1,296.251,
2,304.037, 3456.220, 5,760.200 and 10,368.200 MHz from FM29JW </center>
--