Amps
[Top] [All Lists]

[AMPS] Solid state relays and HV fusing

To: <amps@contesting.com>
Subject: [AMPS] Solid state relays and HV fusing
From: phil@vaxxine.com (Phil T. (VE3OZZ))
Date: Tue, 23 Mar 1999 10:22:58

>
>
>A disadavantage of SSRs in primary supply / soft-start
>switches of a HV transformer is that Triacs continue to conduct
>(in a flashover fault situation) until the next mains zero-crossing.
>It could take up to 10ms at 50Hz to interrupt the fault.
>

Yea I agree. But I don't think mechanical relays on the mains are any
better at this either.  I haven't looked at make/release times for the
usual clunky mechanical units but I don't think they're noted for
lightning-quick response.

>The time constant of a 40uFcapacitor bank with 
>a 50 Ohm fault-current limiting resistor is 2ms.
>
>If a HV fuse in the anode supply interrupts a fault discharge it's
>energy from the capacitors (in a capacitor filter supply) that 
>blows the fuse. 
>
>Then the loss of anode voltage (through interlocking) can
>switch off the PTT and mains supply (but not the blower).
>
>Then the primary-side SSRs don't supply the fault current as
>they wait it out till the next zero-crossing
>
>

Maybe this is why many of these SSRs are available either with zero-cross
or with random operation.  I wondered why they would offer the option when
I was looking at the data sheets.

Good points Mark.

Phil

>Mark G4AXX


--
FAQ on WWW:               http://www.contesting.com/ampfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm


<Prev in Thread] Current Thread [Next in Thread>