>Sub-1800 rpm blowers have a much lower cut-off static pressure
>(0.42 and 0.59, vice 0.80 for the 4C443 and 1.04 for the 4C446).
>The 2200 rpm 4C006 looks like an attractive alternative with a 4 inch
>wheel and 1.58" cutoff static pressure. Might be interesting to try
>this one as an alternative to the higher rpm blowers. It does have
>a note that it must be operated with no less than 0.5" of
>backpressure, a little blockage of the blower outlet would increase
>the backpressure if needed.
I've used a 4C006 and it's fine, although the back pressure is.65 in
so I have no idea what would happen if it were lower. Another interesting
looking one is the 2C646 - 12v motor 1875 RPM and cut off of 1.33 in.
Frank
W2FCA
--
FAQ on WWW: http://www.contesting.com/ampfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
Search: http://www.contesting.com/km9p/search.htm
|