>Just a comment on the bleeder thread... er... string
>
? [chortle]
> I employ a series-parallel configuration in my amplifier power supply.
> The individual resistors are run at about 25% of their ratings. In the
>unlikely event that one of the resistors operated so conservatively
>should fail (open), the second string will still provide a safety bleed.
>
> Also, in my particular application, wherein I source my screen supply
>from the low end of the bleed, a failure would be indicated by a screen
>regulation fault.
>
? Since most amplifiers have a hv voltmeter, an additional source of
bleed exists. In any event, most guys read the voltmeter to see if the
hv filter caps bleed down.
- cheers, Marv
Rich...
R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures
--
FAQ on WWW: http://www.contesting.com/ampfaq.html