If they're wire wound, they ain't non-inductive at RF (at AF maybe).
Anyhow, the 1990 ARRL HB has a nice dummy load project. It uses a true RF
non inductive resistor in 2 gallons of oil that will safely run 1500 watts
for 10 minutes. The actual power rating of the resistor was somewhere
around 100 to 200 watts.
Phil
At 12:34 PM 2/4/99 -0500, you wrote:
>
>That being said, several years ago I built a 50R load containing eight
>series/paralled 100R non-inductive wire wound resistors in a 14" x 17" x
>4" enclosure which was force air cooled. Since the load as built was
>slightly reactive, a series variable capacitor within the enclosure is
>used to provide a near perfect 50R match. This load easily handles up to
>two killowatts for any amount of testing time that might be required.
>Total cost as I remember it was under Can.$40.
>--
>Court
>
>You may communicate with me by using any of the following alternatives:
>
>E-Mail: ve3az@passport.ca
>FAX: 905-294-8756
>Telephone: 905-294-8527
>Canada Post: C.S.Broad
> 32 Wootten Way N.
> Markham ON
> L3P 3L9
> CANADA
>
>
>--
>FAQ on WWW: http://www.contesting.com/ampfaq.html
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>Search: http://www.contesting.com/km9p/search.htm
>
>
>
--