>On Sun, 15 Mar 98 12:35:50 -0800 Rich Measures <measures@vc.net> writes:
>
>>- Eimac publishes no maximum grid-current rating for high Mu triodes,
>>nor recommends specific grid currents.
>
>OH???
>The 3CX800A7 Eimac sheet recommends as "typical" 36ma CW and 16ma two
>tone grid currents at an Ep of 2200VDC.
>Similar recommendations exist for numerous triodes; 3-500Z, 3-1000Z, etc.
>
"Typical" means neither "maximum" nor "recommended", except possibly
within the Conyers city limits.
>Maximum currents are not specified in the sheets but I have a copy of an
>Eimac letter to Amp Supply stating that 50ma is the absolute limit for
>the 3CX800A7.
50mA is not even close to the rated 5w max. grid dissipation, Carl. How
about e-mailing me the JPEG image of this Eimac letter?
BTW, I need some kaput 3cx800A7s to autopsy. If anyone has any, I will
pay the cost of mailing as well any semi-reasonable gratuity.
thanks
cheers
Rich...
R. L. Measures, 805-386-3734, AG6K
--