>At 09:42 AM 11/3/97 +0200, you wrote:
>>Merit,
>>
>> By the way what's the 3-600Z status ?
>Last week I drove down to RFP to pickup some vacuum relays and inquiried
>about the 3-600Z. I spoke with a sales rep that said Svetlana was having
>developement problems and not to expect anything until the first of the
>year at the earliest.
>>
RE: the proposed 3-600Z: The 3-400Z came out first. Then came the
3-500Z. However, the filaments are identical (5v. 14.5a), as are the
emissive capabilities. Thus, there is no difference in the max. SSB PEP
of a 3-400Z and a 3-500Z. Since it seems virtually certain that a 3-600Z
will use the same 5v. 14.5a filament as the other two versions, the SSB
PEP capability of the three will be identical. . . If you are running
a 3-500Z and you need more suds, you don't need a 600w tube, you need a
600w filament transformer.
Rich---
R. L. Measures, 805-386-3734, AG6K
--
FAQ on WWW: http://www.contesting.com/ampfaq.html