>rich asks:
>>How much grid current do you have to run to see an improvement in IMD,
>>Peter?
>
>It peaks about 25mA, as I remember it. 

>From Eimac's curves for the 4-250A, minimal amounts of grid current 
result in a substantive bend in the constant-current curves for the 
grid-driven configuration.  The flatter the curve, the less distortion.  

>As the amp was built for AB1, and
>changed after I put a spec an on it and had a fit, I don't have a grid
>current meter. It has negative feedback with 8.2 ohm carbon resistors in
>the filament returns, ...

It seems to me that putting a cathode RF negative feedback R in the 
filament return (center tap) would result in no distortion-reducing RF 
negative feedback whatsoever, Peter.  
Rich---