Amps
[Top] [All Lists]

[AMPS] SB-220 C4 failure

To: <amps@contesting.com>
Subject: [AMPS] SB-220 C4 failure
From: km1h@juno.com (u nut)
Date: Sun, 06 Jul 1997 10:01:06 EDT
After 25+ years that capacitor has a history of going bad. Simply replace
it. I replace it  as a mater of course whenever I get a SB-220 in for
service. 

73...Carl  KM1H


On Sat, 5 Jul 1997 14:11:43 -0400 (EDT) W7OM@aol.com writes:
>The 20 mfd electrolytic cap in the 120 vdc power supply ruptured.  
>This
>failure occurred with a possible tube short.  Do not believe there is 
>a
>correlation.  Replacement is simple, BUT would like to know if anyone 
>has had
>a similar failure and is this is the effect of another failure.  I 
>will
>replace the rectifier diode too as it shorting would cause the cap to 
>go.
> Diode passes the simple short/reverse resistance checks.
>
>Thanks for comments in advance.
>
>73
>
>Rod
>
>w7om@aol.com
>
>--
>FAQ on WWW:               http://www.contesting.com/ampfaq.html
>Submissions:              amps@contesting.com
>Administrative requests:  amps-REQUEST@contesting.com
>Problems:                 owner-amps@contesting.com
>Search:                   http://www.contesting.com/km9p/search.htm
>

--
FAQ on WWW:               http://www.contesting.com/ampfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm

<Prev in Thread] Current Thread [Next in Thread>