From: measures@vc.net (Rich Measures)
Date: Wed, 2 Jul 97 10:07:04 -0700
>> From:          w8jitom@postoffice.worldnet.att.net
>> To:            marv h. gonsior
To: <amps@contesting.com>
>> Date:          Tue, 1 Jul 97 12:13:33 +0000
>> Subject:       Re: [AMPS] 8877s
>> Priority:      normal
>
>Marv,
>
>I tried e-mailing this to you, but it bounced. 
>
>> > A number of postings have made reference to a certain time span wherein
>> > Eimac was having processing problems with their 8877. IF this is true,
>> > would someone kindly let me know what info they have on this?  Thanks.
>> 
>> Hi Marv,
>> 
>> The 8877 was always a difficult tube to manufacture, but through the 
>> mid to late 80's the tubes were failuer prone.
>> 
>> They had gold sputtering problems and grid to cathode shorts, Eimac 
>> said this was related to air pollution in Salt Lake City 
>> contaminating materials...snip..

Mr. Rauch:  Was the information from Eimac written or verbal?  
thanks
Rich---

R. L. Measures, 805-386-3734, AG6K   


--