Amps
[Top] [All Lists]

[AMPS] Filament breakage

To: <amps@contesting.com>
Subject: [AMPS] Filament breakage
From: measures@vc.net (Rich Measures)
Date: Wed, 14 May 97 20:13:26 -0700
>Hi Carl,
> 
>> I doubt if a "mature" 811A is outgassing Tom....good dance try though. 
>
>Why the personal comments implying I am telling a "story"? If you'd 
>listen as much as you spew insults, you'd learn.
I don't think Carl is making a personal comment, Tom.   During the vhf 
parasitics debate, there were a number of issues you tap danced around.  
You appear to be on the same course in this discussion. .   
>ALL tubes, no matter how "mature", outgas. Outgassing is a normal 
>part of the life of the tube. 
The problem is that the tubes which have the problem typically do not 
show signs of abnornal gas.  Out of the 5, kaput 3-500Zs we tested 
Monday, none appeared to have a gas problem.  However, all of them had 
bent filament helices  If gas was the cause of the problem, where did the 
gas vanish to? 
Rich---

R. L. Measures, 805-386-3734, AG6K   


--
FAQ on WWW:               http://www.contesting.com/ampfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com