Hello Robert and all.

First of all the 3-500Z must be stored in a vertical position. Many
friends have had the misfortune of buying a new set of spares only to
find them shorted upon use many years later. All of them were stored on
their sides. I'm not saying that it is a certantity, just that it does
happen. 

The gas factor is one that I have been unable to pin down, possibly
others might wish to comment. What I have seen, on occassion, is a
customer bring in an SB220 or the like that has been idle for many years
that has a gassy tube. As near as I can discover they were all Eimac
tubes with 1985-90 era date codes. Those old 1970's era tubes seem to be
bullet proof. 

Some of the early Chinese tubes had many problems which appear to be
rectified.

I hope this helps a bit.

GL and 73   Carl   KM1H