> > Copper clad aluminum, rings not spiral, OD of outer conductor is 1”. OD of
> > inner is 3/8”. Outer conductor is copper. I think you are on right track.
> > Measurements were all done with a steel tape measure as best I could.
After I responded I realized I might have an old Cablewave catalog with specs
for that cable in it, and sure 'nuff, I found one. Here are specs:
FLC78-50J
Center OD: 0.357"
Outer ID: 0.850"
OuterOD: 0.990"
Jacket OD: 1.124"
VF: 88%
Connector part numbers:
738828 Type N male
738829 Type N female
738833 UHF male
738832 UHF female
738831 7/8" flange
Let me know if you want me to look for connectors, or if you want a pic of the
catalog page. 73.
--- Jeff WN3A
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com