Towertalk
[Top] [All Lists]

Re: [TowerTalk] Guy tension gauge

To: john@kk9a.com
Subject: Re: [TowerTalk] Guy tension gauge
From: "Steve, NR4M" <steve@nr4m.com>
Date: Thu, 26 Nov 2020 11:26:19 -0500
List-post: <mailto:towertalk@contesting.com>
Think we’re all essentially in agreement. 
 
Enjoy thanksgiving. 

Steve
Sent from my iPhone

> On Nov 26, 2020, at 10:22 AM, john@kk9a.com wrote:
> 
> If your tower is plumb and you have perfectly level ground with equal anchor
> spacing and have a pier pin base the guys will have equal tension.  I use a
> transit level and a Loos gauge for my towers. I believe that the Loos is
> accurate enough for my towers.  I am more concerned that the tower it plumb
> over equal tension on each guy although if I recall they seems reasonably
> equal because I adjusted my anchor spacing for the unlevel ground.
> 
> 73 and happy Thanksgiving,
> 
> John KK9A (W4AAA in last weekend's SS contest)
> 
> 
> Steve lists at oakcom.org
> 
>> On 11/25/2020 7:39 PM, Steve, NR4M wrote:
>> 
>> What is the Loos gauge telling you?
>> Those things were intended for the type of cable used on boat rigging.
> They probably do that just fine.
>> The finer stranding of the boat cable deflects more easily than the EHS
> cable would, so I think all bets are off as far as accuracy goes.
>> The best you can do with a Loos gauge, and it probably does it just fine,
> is show you if the EHS tension is equal.
>> But, if I recall my physics correctly, -if- all guys at any given level
> are identical ( same distance to each guy anchor, etc) then the tension on
> any one will be the same as the other two.
>> I have a nice, brand new tension dynamometer and I have been intending for
> several years on taking pieces of 3/16, 1/4, 5/16 and 3/8 inch EHS, putting
> them in series with each other and the dynamometer between BIG trees, and
> try and calibrate a large Loos gauge.
> 
> Mostly correct. If you consider the tower as a flexible column, the three
> guys at any level will be fairly equal in tension. Anyone who installs
> taller R45 & R55 towers knows that intuitively. If it were a rigid column,
> not so much. It so happens though that even big towers when engineered for
> maximum efficiency turn out to be fairly flexible because the guy levels are
> spaced way further apart.
> 
> When I mentioned deflection gauge I was thinking of something like a
> Penn-Tech, which comes with a table letting you measure either EHS or bridge
> strand *fairly* accurately.
> 
> -Steve K8LX
> 
> 
> 
> Scanned by McAfee and confirmed virus-free.    
> Find out more here: https://bit.ly/2zCJMrO
> 
> _______________________________________________
> 
> 
> 
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>