Byron,
I would think you would be fine if you put a steel sleeve over the 5/8
inch bolt, of the correct length to allow you to tighten the bolt properly.
If you used a piece of 7/8 inch dia steel (or 1 inch dia), with a 1/8
inch wall thickness, it would make a fine place to hang a guy wire thimble.
73 de Steve, NR4M
On 4/16/2019 9:18 PM, Byron Tatum wrote:
Hello- I have always used the "older style" Rohn 45G guy brackets that have two of 5/8" bolts at the guy attachment points. One
bolt (inner one) secures bracket and rests against tower leg, the other bolt (outer one) is for attachment of torque arm piece or a guy wire thimble.
I bought some of the "newer style" 45G guy brackets that were incomplete, all I got was the large pieces. I bought the 3 of smaller inner
bracket pieces that bolt to interior of bracket from a Rohn supplier, but I did not think to get the washers and guy attachment ring pieces that attach to the
single 5/8" bolt out at guy bracket ends. I was studying the drawing for this style bracket and it appears to me that the washers and
"guy attachment ring" are probably necessary. I thought I would ask someone that has attached these style brackets if you could use a thimble in there
instead of the ring. Possibly the single bolt tightens up against the washers and ring, and is necessary to have correct thickness in there.Thanks,Byron
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|