OK, I see the issue. Like Rick, I used to use N connectors and abandoned
them because of the center pin migration.
I now only use good quality Amphenol PL-259's and everything has been fine.
I am anal about sealing all the Pl-259 connections but that is another topic in
itself. hihi
73,
Bob
K6UJ
On Jun 5, 2015, at 8:15 PM, Richard (Rick) Karlquist <richard@karlquist.com>
wrote:
On 6/5/2015 8:00 PM, Roger (K8RI) on TT wrote:
My experience shows "to me" that those using N-type connectors on
vertical runs without problems are quite lucky.
Coax with type N connectors is quite capable of center pin
migration in or out just laying on the ground. About
20 years ago, I bought a bunch of 43 foot long 9913 cables
with type N's at a swap meet. They came coiled up and I
just threw them in storage. By now, every single one of
them has the center pins sticking out both ends like
pinocchio. The ones that I used early on that got
straightened out for a while, but then were rolled up
did better.
I had some 500 foot runs of coax laying out on the ground
and over time, the center conductor migrated.
Going forward, I use PL259's exclusively to avoid this problem.
Except on my 7/8 inch coax.
Rick N6RK
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk