I have boxes at the base of my towers. I use only 6 control justion 123
and 567 on CDR, TELEX rotors and double the extra #4 and #7 to #1 and #2
to over come some IR loss and the Motor Starting CAP at the base of the
tower and full 1 through * up the tower to rotor.
When I did not have a BOX at the bottom I put the Cap in a junction box at
the top of the tower and the junction connection to the rotor ;
Wayne W3EA
> Date: Wed, 22 Oct 2014 19:46:13 -0700
> To: towertalk@contesting.com
> From: w7cs@theriver.com
> Subject: [TowerTalk] Sluggish Ham 4
>
> Ray,
>
> The phasing capacitor, an AC one, can lose its capacity with
> age. Most times a sluggish rotator can be corrected with a new
> capacitor. An over abundance of capacitance and voltage rating, in
> the new AC capacitor, doesn't seem to affect the rotator's new
> performance . You will probably have difficulty in getting the exact
> rating and size locally. I've even had to mount a new larger sized
> capacitor externally to the control box. Fortunately its leads go
> across two of the external interface terminals.
>
> Chuck, W7CS
>