To: | towertalk@contesting.com |
---|---|
Subject: | Re: [TowerTalk] grounding entrance panel thickness |
From: | Jim Lux <jimlux@earthlink.net> |
Date: | Sat, 15 Feb 2014 12:29:19 -0800 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
On 2/15/14 12:20 PM, Jorge Diez - CX6VM wrote: Hello Going to buy a piece of copper to be used as the entrance panel to screw all surge control lines arrestors. 1/8 thickness will be enough or is better a wider panel for a better grounding? more than thick enough. you could go with something significantly thinner (1/16th or even down to 0.020"). It's more about mechanical things at that point. You'd want to have the copper on top of something more rugged. Aluminum also works, unless you need to solder to it. _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |