On 2/15/14 12:20 PM, Jorge Diez - CX6VM wrote:
Hello



Going to buy a piece of copper to be used as the entrance panel to screw all
surge control lines arrestors.



1/8 thickness will be enough or is better a wider panel for a better
grounding?



more than thick enough. you could go with something significantly thinner (1/16th or even down to 0.020").

It's more about mechanical things at that point. You'd want to have the copper on top of something more rugged.


Aluminum also works, unless you need to solder to it.