Towertalk
[Top] [All Lists]

[TowerTalk] Fwd: Fwd: Aluminum Towers -- Tower Installer in S.F. Bay Are

To: towertalk@contesting.com
Subject: [TowerTalk] Fwd: Fwd: Aluminum Towers -- Tower Installer in S.F. Bay Area??
From: Hans Hammarquist <hanslg@aol.com>
Date: Mon, 13 Aug 2012 18:11:20 -0400 (EDT)
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
At minimum, tie the guy wire around the cross members and the leg. The most 
common problem is that the leg can be ripped off the cross member (which really 
weakens the tower).


In my case I have a large plate that is tied to the legs. That is to eliminate 
the forces on the welding between the cross member and tower leg.



Hans - N2JFS



-----Original Message-----
From: K8RI <K8RI-on-TowerTalk@tm.net>
To: towertalk <towertalk@contesting.com>
Sent: Mon, Aug 13, 2012 2:39 pm
Subject: Re: [TowerTalk] Fwd: Aluminum Towers -- Tower Installer in S.F. Bay 
Area??


On 8/13/2012 1:10 PM, Jerry Gardner wrote:
> This is really great information. Thanks everyone! I think I have enough
> info to go ahead with an aluminum tower installation. Next step is to get
> the engineering calculations that the County requires done and submit an
> application for a building permit.
>
> After that I'll need someone to do the installation work -- does anyone
> know of a tower installer in the S.F. Bay Area? I'm having a hard time
> finding anyone local. Someone from outside the area, while a possibility,
> will drive the cost up as I'll have to pay travel expenses.
>

Remember that guys should attach to a bracket or saddle that fits around 
the tower, not tied around each leg. If there are none made for the 
particular tower then we should have the required brackets fabricated. 
It will really be doing the tower a favor as it removes *all* lateral 
force exerted by the guys on the tower let alone individual legs and 
leaves only the vertical component. Remember when the wind is blowing 
the upwind leg us the only thing resisting all that lateral force when 
the guys are fastened to the tower legs instead of using a properly 
designed and installed bracket.

Yes I know many of us, including me, have gotten away with fastening 
guys to tower legs, but no more at least for me once I did the 
calculations as to how much force the upwind leg has to withstand in 
addition to the force exerted by the guys.  It only takes a little trig 
to come up with some scary figures.

73 and good luck

Roger (K8RI)


> - 73, Jerry
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

 

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>