Towertalk
[Top] [All Lists]

Re: [TowerTalk] Crankup Tower Maintainance

To: KJ6Y@aol.com
Subject: Re: [TowerTalk] Crankup Tower Maintainance
From: w2lk@bk-lk.com
Date: Mon, 03 May 2010 12:45:35 -0700
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
Well my UST HDX589MDPL has a separate uphaul and downhaul cable. These
do not connect to each other and are fixed to the drum. The drum spools
on one cable and spools off the other at the same time depending on
whether it's raising or lowering.
I am at work and won't be home until Wednesday morning so I can't check
but I am pretty sure this is the case.


Les W2LK


  -------- Original Message --------
 Subject: Re: [TowerTalk] Crankup Tower Maintainance
 From: KJ6Y@aol.com
 Date: Mon, May 03, 2010 3:28 pm
 To: richard@karlquist.com, w2lk@bk-lk.com
 Cc: w7wll@arrl.net, towertalk@contesting.com
 
  I think you guys are thinking of two different motor drives.  The US
Tower ( and some Tristao and Tri-EX) MDP-750 is a continous cable for
pull up and pull down and wraps around a multi grooved pulley system. 
The MDPL-1000 is a drum with two seperate calble, one for pull up and
the other for pull dowm.
I have seen the MDP-750 cable slip if it too loose or too slippery.  
Skip, KJ6Y
Communications Service Co
22712 Califa St
Woodland Hills, CA 91367 
818-887-3569