1) In general, ALL grounds must be bonded together for lightning 
protection.

See http://audiosystemsgroup.com/SurgeXPowerGround.pdf

2) A connection to earth does not make an antenna work better, 
but it does make it safer. 

3) Some antennas (most verticals) DO work against a radial system 
or counterpoise that accepts antenna current and interacts with 
the near electric and magnetic fields of the antenna. Those 
radials or counterpoise do NOT need a connection to earth. 

4) The radio waves produced by the electromagnetic field from the 
antenna DO interact with the earth in at least two ways. First, 
they are reflected from the earth in the far field, and that 
reflection is a major contribution to the vertical radiation 
pattern of the antenna. Second, what we call "ground wave" 
propagation is an interaction of the wavefront with the earth.  
NEITHER OF THESE MECHANISMS USE A CONNECTION WITH THE EARTH. 

Bottom line: An earth connection is very important for SAFETY. 
That's ALL! And in general, all earth connections must be bonded 
together for SAFETY. 